The espresso shot keeps running past the normal programmed volume and does not stop automatically.
Possible Causes
- The programmed shot volume has been changed from the factory setting.
- The flow meter is dirty and not accurately detecting water flow.
- The espresso shot is under-extracted, causing longer brew times and more liquid output.
Procedure
| Step | Instructions |
|---|---|
| 1 | Reset or reprogram the shot volume (Volumetric machines) If your machine is volumetric, you can either:
|
| 2 | Dial in your coffee beans (Time-based machines) For time-based models, adjust the grind size, dose, and tamp to achieve proper extraction time. A finer grind and correct dose help regulate shot volume and prevent over-brewing. |
| 3 | Descale the machine Run a descale cycle using Sage Descaling Solution to clean the internal water pathways and the flow meter. This helps restore accurate shot volume control. |
Quick Facts
- Volumetric machines (no coffee, just water):
- 1 Cup button: slightly over 1 oz (≈30–35 mL)
- 2 Cup button: slightly over 2 oz (≈60–70 mL)
- Time-based machines (no coffee, just water):
- Single shot: approximately 4–6 oz (≈120–180 mL)
- Double shot: approximately 6–8 oz (≈180–240 mL)
Volumetric based machines include: SES870 Barista Express®, SES878 Barista Pro™, SES880 Barista Touch™, SES881 Barista Touch™ Impress, SES876 Barista Express Impress, SES450 Bambino™, and SES500 Bambino® Plus
The SES920 Dual Boiler™, SES980 Oracle®, and SES990 Oracle® Touch have time-based extraction by default, but can also toggle to use volumetric control through the advanced features. The shot duration/volume can also be reprogrammed for the SES980 and SES990.